Thermal insulation to external walls in the bill of quantities
| Unit | m² |
|---|---|
| Category | Thermal insulation |
| Division | Waterproofing and thermal insulation |
The item as worded in the bill
Supply and install an external thermal insulation system to the building façades in extruded polystyrene boards 5 cm thick, bonded to walls, columns and beams and secured with mechanical fixings, then covered with a cementitious base coat reinforced with alkali-resistant glass fibre mesh, complete with corner beads and starter track; the rate includes opening reveals and external scaffolding.
Method of measurement
Measured in square metres of the net insulated façade area after deducting openings, taken on the outer face and including the columns and beams covered. Opening reveals are measured by the linear metre or their area added, as the preambles provide. Mesh, fixings and beads are not measured separately. Where the item is limited to insulating columns and beams alongside insulated block, only their outer faces are measured.
What the unit rate covers
- Insulation boards of the specified thickness and type
- Adhesive and mechanical fixings
- Base coat reinforced with fibre mesh
- Corner beads, starter track and reinforcement at opening corners
- Opening reveals
- External scaffolding
Priced separately
- Final finishing coat or paint
- Stone cladding and its fixing system
- Window sills
- Sealant to joints around aluminium frames
Specification and reference
The energy conservation code, SBC 601 or 602 by building type, sets the thermal performance required of the external wall and the treatment of thermal bridges. SBC 201 and 801 requirements on combustible façade insulation are consulted, especially for high-rise buildings. Polystyrene boards conform to ASTM C578, and the complete system comes from one source, to its manufacturer’s instructions.
What moves the rate
- Insulation board type and thickness
- Building height and scaffolding
- Number of openings, projections and details
- Fire requirements that may impose rock wool
Common pricing mistakes
- Pricing boards and adhesive only and leaving out the fixings, mesh, base coat and corner beads that complete the system.
- Forgetting opening reveals, heads and sills, which are insulated with thinner boards and take more labour.
- Overlooking that insulated block does not remove the need to insulate the faces of external columns, beams and slab edges.
- Pricing polystyrene on a high-rise building where fire requirements impose a non-combustible insulation material.
Related calculators and terms
More items in Thermal insulation
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.
Start nowجرّب بلا تسجيل