Cementitious waterproofing to wet areas in the bill of quantities
| Unit | m² |
|---|---|
| Category | Wet areas and tanks waterproofing |
| Division | Waterproofing and thermal insulation |
The item as worded in the bill
Supply and apply two-component polymer-modified flexible cementitious waterproofing to bathroom, kitchen and laundry floors and walls, in two coats brushed at right angles, about 2 mm thick in total, with mesh at corners and floor drains, turned up the walls 30 cm above finished level and full height in the shower zone; the rate includes a 24-hour ponding test.
Method of measurement
Measured in square metres of each wet room’s net floor area plus the area turned up the walls: room perimeter times upstand height, and shower walls to full height. The door opening is deducted from the perimeter and its threshold added. Coats do not multiply the area, and mesh is not measured separately. Dimensions run from the plaster face, not wall centre lines, room by room off the plans.
What the unit rate covers
- Cleaning and dampening the surface before application
- Mixing the two components in the stated proportion
- Two brushed coats with drying time between them
- Reinforcing mesh at corners, drains and pipes
- Mortar fillets at corners
- Ponding test and repair of defects
Priced separately
- Wall plaster under the waterproofing
- Screed to falls or protection over the waterproofing
- Tiles and their adhesive
- Floor drains and their fixing
Specification and reference
The item follows the project technical specification and the manufacturer’s data sheet, which set the mixing ratio, coverage per coat and waiting time before tiling, with the Saudi Building Code requirements in SBC 201 and 701 for water-resistant surfaces in bathrooms and showering areas. The waterproofing must be compatible with the tile adhesive over it, as the manufacturer recommends.
What moves the rate
- Upstand height on walls and extent of shower zones
- Number of wet rooms and their small areas
- Material type: flexible two-component or rigid single-component
- Number of penetrating pipes and drains
Common pricing mistakes
- Measuring floors only although the area turned up the walls may equal or exceed it in small bathrooms.
- Taking off the bathrooms and forgetting kitchens, laundry rooms, balconies and pump rooms named in the specification.
- Pricing a rigid single-component material where the specification states a flexible two-component one.
- Ignoring the effect of the ponding test on sequencing when dozens of bathrooms must be tested before tiling is allowed.
Related calculators and terms
More items in Wet areas and tanks waterproofing
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.
Start nowجرّب بلا تسجيل