Home › BOQ items guide › Waterproofing and thermal insulation › Roof waterproofing › Roof screed laid to falls

Roof screed laid to falls in the bill of quantities

Unitm² (or m³)
CategoryRoof waterproofing
DivisionWaterproofing and thermal insulation

The item as worded in the bill

Supply and place lightweight foamed concrete screed on the roof slab, not less than 5 cm thick at the outlets and laid to the falls shown on the drawings, of the specified density and strength, with level guides set and the surface finished to receive waterproofing; the rate includes cleaning the slab, angle fillets at the parapet and curing.

Method of measurement

Measured in square metres of the net horizontal area between the parapet faces with the average thickness stated, or in cubic metres as area times average thickness. The average derives from the minimum thickness at the outlet, the fall and the longest distance water travels, not from the minimum alone. Small equipment plinths are not deducted, nor fillets measured separately. Outlet positions come from the roof drainage drawing.

What the unit rate covers

Priced separately

Specification and reference

The project technical specification sets the concrete type, density and strength, and roof drainage requirements are in Saudi Building Code SBC 201 and 701. The structural engineer checks the screed weight within the dead loads under SBC 301; hence lightweight concrete is preferred where drainage runs are long and thickness grows.

What moves the rate

Common pricing mistakes