Roof screed laid to falls in the bill of quantities
| Unit | m² (or m³) |
|---|---|
| Category | Roof waterproofing |
| Division | Waterproofing and thermal insulation |
The item as worded in the bill
Supply and place lightweight foamed concrete screed on the roof slab, not less than 5 cm thick at the outlets and laid to the falls shown on the drawings, of the specified density and strength, with level guides set and the surface finished to receive waterproofing; the rate includes cleaning the slab, angle fillets at the parapet and curing.
Method of measurement
Measured in square metres of the net horizontal area between the parapet faces with the average thickness stated, or in cubic metres as area times average thickness. The average derives from the minimum thickness at the outlet, the fall and the longest distance water travels, not from the minimum alone. Small equipment plinths are not deducted, nor fillets measured separately. Outlet positions come from the roof drainage drawing.
What the unit rate covers
- Cleaning and dampening the roof slab
- Setting level guides or points to the falls drawing
- Supply of lightweight concrete and pumping to the roof
- Levelling and smoothing to receive waterproofing
- Angle fillets at the parapet
- Curing
Priced separately
- Waterproofing and thermal insulation
- Roof outlets and their pipes
- Concrete equipment plinths
Specification and reference
The project technical specification sets the concrete type, density and strength, and roof drainage requirements are in Saudi Building Code SBC 201 and 701. The structural engineer checks the screed weight within the dead loads under SBC 301; hence lightweight concrete is preferred where drainage runs are long and thickness grows.
What moves the rate
- Average thickness resulting from the number and spacing of outlets
- Concrete type: lightweight foamed or normal
- Building height and means of pumping
- Roof area and the number of obstructions on it
Common pricing mistakes
- Pricing the item on the minimum thickness at the outlet although the thickness at the farthest point is several times that.
- Converting square metres to cubic metres with an assumed thickness without consulting the falls drawing and outlet positions.
- Pricing normal concrete where the specification requires lightweight foamed concrete, or the reverse; material, pumping and weight all differ.
- Forgetting falls to the stair room roof and open balconies, cast in the same material in small scattered quantities.
Related calculators and terms