Roof thermal insulation with polystyrene boards in the bill of quantities
| Unit | m² |
|---|---|
| Category | Thermal insulation |
| Division | Waterproofing and thermal insulation |
The item as worded in the bill
Supply and install roof thermal insulation in extruded polystyrene boards 5 cm thick, of the specified density and compressive strength, laid over the tested waterproof membrane with edges tightly butted and joints staggered and cut neatly around outlets and plinths; the rate includes a geotextile separation layer over the boards and their protection until the tile layer is laid.
Method of measurement
Measured in square metres of the net horizontal area covered by boards between the parapet faces, deducting large equipment plinths and the stair room. Nothing is added for cutting and wastage. For insulation in two layers the total thickness is stated and the area is not doubled. Vertical parts are measured only if the details show insulation there. The separation layer falls within the item where so stated.
What the unit rate covers
- Supply of boards and storage away from sun and flame
- Laying boards tightly butted with staggered joints
- Cutting around outlets, pipes and plinths
- Geotextile separation layer
- Temporary restraint of boards against wind until covered
Priced separately
- Waterproof membrane under the boards
- Protection screed or tiles over them
- Thermal insulation of the parapet
Specification and reference
Insulation thickness and thermal resistance are set under the Saudi energy conservation code: SBC 602 for low-rise residential buildings and SBC 601 for others. Polystyrene boards conform to ASTM C578 as to type, compressive strength and water absorption. The material’s thermal properties certificate must be submitted and approved, and the insulation requirements tied to the electricity connection met.
What moves the rate
- Board thickness and number of layers
- Type, extruded or expanded, and compressive strength grade
- Roof shape and amount of cutting around obstructions
- Building height and means of hoisting the boards
Common pricing mistakes
- Pricing expanded polystyrene where the specification requires extruded with a stated compressive strength able to carry tiles and maintenance traffic.
- Adopting the customary 5 cm thickness without checking the thickness required by the project’s thermal calculation.
- Forgetting the separation layer over the boards, so tile mortar seeps between joints and thermal bridges form.
- Leaving boards exposed to sun and wind for days, then bearing the cost of replacing damaged and blown-away boards.
Related calculators and terms
More items in Thermal insulation
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.