Stiffener columns and beams for walls in the bill of quantities
| Unit | lin. m (or m³) |
|---|---|
| Category | Lintels and wall stiffeners |
| Division | Masonry works |
The item as worded in the bill
Supply and cast reinforced concrete stiffener columns and beams grade C25, 20×20 cm in section, within block walls at the positions and spacing set by the structural general notes, reinforced with four longitudinal bars and stirrups; the rate includes dowels fixed into the slabs, formwork, placing, curing and toothing of the blockwork at the column.
Method of measurement
Measured by the linear metre with the section stated, or by the cubic metre. Column length runs from the slab surface to the soffit of the slab or beam above, and beam length between faces of structural or stiffener columns. Quantities come from applying the general-notes rule to each wall, as these members are seldom drawn on the plans. Dowels and formwork, when included, are not measured separately.
What the unit rate covers
- Concrete, reinforcing bars and stirrups
- Dowels into the slab below and above
- Formwork to two faces, with the toothed blockwork forming the sides
- Hand placing in lifts and compaction
- Curing and striking formwork
Priced separately
- Adjacent blockwork
- Lintels over openings
- Thermal insulation of stiffeners in external walls
Specification and reference
The structural general notes set the maximum wall length and height without stiffening and the section and reinforcement of stiffeners, based on Saudi Building Code SBC 305 for the stability of non-load-bearing walls and SBC 304 for concrete members. Wind and seismic loads in SBC 301 are considered for parapets and high external walls. Steel conforms to ASTM A615.
What moves the rate
- Storey heights and uninterrupted wall lengths
- Number of free ends and wide openings
- Dowels cast in beforehand or drilled and fixed later with epoxy
- Scattered members and small volume of each pour
Common pricing mistakes
- Dropping the item altogether because stiffeners are mentioned only in the general notes and do not appear on the architectural plans.
- Applying the spacing rule to external walls and forgetting long internal partitions and walls of high storeys such as halls.
- Ignoring the cost of drilling and fixing dowels with epoxy when they were not left in the slabs before casting.
- Forgetting the small columns at both sides of wide openings and at free wall ends not joined to a column.