Insulated blockwork for external walls in the bill of quantities
| Unit | m² |
|---|---|
| Category | Insulated and lightweight block |
| Division | Masonry works |
The item as worded in the bill
Supply and build external walls in insulated concrete blocks 40×20×20 cm with a continuous polystyrene layer of the thickness that achieves the required thermal transmittance, laid in cement–sand mortar with the mortar bed interrupted at the insulation layer; the rate includes corner and half units, ties, bed-joint reinforcement, scaffolding and submission of the thermal test certificate.
Method of measurement
Measured in square metres of the net external wall area after deducting openings and concrete columns and beams, which the block does not cover and are insulated under another item. Length is taken on the outer face between columns, height from slab to beam soffit. Corner and half units are not measured separately, nor is wastage added. The item is kept apart from the ordinary block of internal partitions.
What the unit rate covers
- Supply of insulated blocks with special units for corners and opening jambs
- Mortar laid so the insulation layer stays continuous at the joints
- Ties to the concrete columns and reinforcement in the bed joints
- External scaffolding and hoisting
- Thermal performance test certificate from an accredited laboratory
- Cutting and breakage wastage
Priced separately
- Insulation of external column and beam faces
- Lintels and stiffener columns
- External and internal plaster
Specification and reference
Laying is governed by Saudi Building Code SBC 305, while SBC 602 for low-rise residential buildings and SBC 601 for others set the thermal performance required of the external wall. A test certificate of the block’s thermal transmittance from an accredited laboratory needs the engineer’s approval, and the insulation requirements tied to connection by the Saudi Electricity Company apply.
What moves the rate
- Thickness and type of the polystyrene layer and the transmittance required
- Aggregate type: normal or lightweight volcanic
- Availability of special units and distance from the factory
- Building height and the need for external scaffolding
Common pricing mistakes
- Pricing a block with separate polystyrene inserts in the cores although the specification calls for a continuous insulation layer.
- Measuring all the building’s walls in insulated block when it is required for external walls only, not partitions.
- Leaving out the insulation of external columns and beams on the assumption that insulated block alone achieves the insulation.
- Relying on a supplier’s price without an approved thermal test certificate, so the engineer rejects the material after award.