Natural stone facade cladding in the bill of quantities
| Unit | m² |
|---|---|
| Category | Facade cladding |
| Division | Flooring and cladding |
The item as worded in the bill
Supply and fix facade cladding in approved natural limestone 3 cm thick, with the face finish shown on the drawings, mechanically fixed on stainless steel angles, anchors and expansion bolts into concrete and solid blockwork, with an air cavity behind the stone and regular joints filled with flexible sealant; the rate includes shop drawings, calculations, scaffolding and cleaning.
Method of measurement
Measured in square metres of net clad area from the elevation drawings, deducting openings and adding their clad reveals. Corners and columns are measured on their developed area. Sills, heads, copings, stone cornices and mouldings are measured in linear metres under separate items because they are thicker worked pieces. The fixing system and joints are not measured separately, and insulation behind the stone is outside this item unless stated.
What the unit rate covers
- Stone slabs of the approved thickness and finish
- Stainless steel angles, anchors and bolts
- Drilling or slotting of slabs to receive the anchors
- Shop drawings and structural calculations
- Joint sealant and backer rod
- Scaffolding and final cleaning
Priced separately
- Thermal insulation and waterproofing behind the cladding
- Sills, heads, copings and mouldings
- Secondary steel sub-frame where needed and not stated
- Water-repellent treatment where a separate item exists
Specification and reference
Limestone complies with ASTM C568 and granite with ASTM C615. Fixings are designed for slab weight, wind and seismic loads under the loading code SBC 301, and exterior wall coverings fall under the general building code SBC 201. Anchors are stainless steel, and the energy code SBC 601 or SBC 602 governs insulation behind the cladding.
What moves the rate
- Stone type, thickness and face finish
- Fixing method, mortar or mechanical
- Building height and scaffold duration
- Number of openings, corners and special pieces
Common pricing mistakes
- Pricing 2 cm stone as used for mortar fixing on a mechanically fixed facade that needs greater thickness to take the drilling and anchors.
- Allowing galvanised steel fixings instead of the stainless steel the specification requires, with a large price difference between them.
- Overlooking corner pieces mitred at 45 degrees or L-shaped returns, which are specially made and increase waste.
- Deducting openings without adding their deep reveals in thick insulated walls; on a facade with many windows the reveal area is not small.