Glass-fibre reinforced concrete facade elements in the bill of quantities
| Unit | m² (or lin. m for cornices, or No. for single elements) |
|---|---|
| Category | Facade cladding |
| Division | Flooring and cladding |
The item as worded in the bill
Supply and fix facade elements in alkali-resistant glass-fibre reinforced concrete, comprising panels, cornices, window surrounds and screens as the drawings, with a skin thickness not less than specified, with cast-in galvanised steel inserts and brackets for fixing, mechanically fixed to the concrete structure, including flexible sealant to joints and final painting in the approved colour.
Method of measurement
Panels and screens are measured in square metres of exposed face area; cornices, surrounds and mouldings in linear metres with the profile girth stated; and single elements such as capitals, columns and domes by number. Returns, hidden edges and fixings are not measured. Perforated screens are measured on their overall area with no deduction for voids. The item states whether painting is included, since some bills measure it separately.
What the unit rate covers
- Moulds and factory production of the elements
- Cast-in inserts, brackets and fixings
- Transport, hoisting and fixing on site
- Flexible sealant to joints
- Shop drawings and fixing calculations
- Scaffolding or lifting plant
Priced separately
- Secondary supporting steel frame unless stated
- Final painting where a separate item exists
- Integrated lighting behind screens
Specification and reference
These elements are governed by the project specification and the manufacturer’s data for alkali-resistant glass-fibre content, skin thickness and flexural strength, proven by tests on production samples. Fixings are designed for element weight, wind and seismic loads under SBC 301, and exterior wall coverings fall under the Saudi general building code SBC 201, with joints left to allow thermal movement.
What moves the rate
- Complexity of shape and number of different moulds
- Repetition of the same element from one mould
- Element size, weight and fixing height
- Face finish: smooth for paint or integral colour and texture
Common pricing mistakes
- Spreading mould cost over a small non-repeating quantity without noticing that a special mould consumes a large part of the element price.
- Measuring cornices in square metres of developed face in the offer while the bill asks for linear metres, so quantity and rate diverge from competitors.
- Leaving out the secondary steel frame needed to carry projecting elements and deep cornices away from the concrete face.
- Forgetting crane hoisting and safe site storage for large elements with fragile edges that break under careless handling.
Related calculators and terms
More items in Facade cladding
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.
Start nowجرّب بلا تسجيل