Decorative wall panels in the bill of quantities
| Unit | m² |
|---|---|
| Category | Decorative finishes |
| Division | Plaster, paint and gypsum works |
The item as worded in the bill
Supply and fix decorative wall panels to internal walls, of the type, thickness and finish shown in the finishes schedule, fixed to a sub-frame of treated timber battens or metal sections, or with approved adhesive on a true surface, including end, joint and base trims and cut-outs around switches and outlets; the rate includes samples and a mock-up panel.
Method of measurement
Measured in square metres of visible area actually clad, deducting doors, windows and unclad areas and adding returns at reveals where clad. Cutting waste arising from panel size is not measured, nor are the sub-frame and trims. Fluted panels are measured on their flat area, not the developed surface. Different panel types are given in separate items.
What the unit rate covers
- Panels in the approved finish and colour
- Sub-frame or adhesive and concealed fixings
- End trims and jointing profiles
- Cut-outs around switches and outlets
- Protection of panels until handover
Priced separately
- Levelling or plastering of the wall behind the panels
- Integrated concealed lighting and its wiring
- Acoustic insulation behind panels unless stated
Specification and reference
The finishes schedule and specification fix the panel material, thickness and finish. The Saudi general building code SBC 201 requires interior wall finishes to achieve the flame-spread and smoke-developed classification for the occupancy, demonstrated by testing to ASTM E84 or equivalent. Timber is treated against fire and insects where required, and fixing follows the manufacturer’s instructions and the approved sample.
What moves the rate
- Panel material and finish: natural veneer, plastic composite or acoustic fabric
- Fixing method, on a sub-frame or by direct adhesive
- Wall layout and ratio of cut to full panels
- Fire classification or acoustic performance requirement
Common pricing mistakes
- Working out the purchase quantity straight from the net area, although panels come in fixed sizes and the offcut is lost at every wall.
- Overlooking the sub-frame and wall levelling; panels glued to uneven plaster show their waviness under raking light.
- Forgetting the system’s own end trims, corner profiles and base trim, which are sold by the linear metre and recur at every edge.
- Pricing a standard panel for a corridor or exit that demands a higher fire classification, then having the material rejected at submittal.
Related calculators and terms
More items in Decorative finishes
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.
Start nowجرّب بلا تسجيل