العربية Try the demo Start now
Home › BOQ items guide › Concrete works › Superstructure concrete › Reinforced concrete columns

Reinforced concrete columns in the bill of quantities

Unitm³
CategorySuperstructure concrete
DivisionConcrete works

The item as worded in the bill

Supply and pour reinforced concrete for columns on all floors, grade C35 with ordinary Portland cement, to the sections and reinforcement shown in the column schedule and structural drawings; the rate includes vertical bars, ties, smooth-faced formwork with its bracing and plumbing, chamfer strips, vibration and curing.

Method of measurement

The column volume is its section multiplied by its clear height from the top of the slab or tie beam to the soffit of the slab or beam above, floor by floor because the section changes with height. The part within the slab thickness is not counted with the column. Circular columns are taken at their actual sectional area and given a separate item where their rate differs.

What the unit rate covers

Priced separately

Specification and reference

Columns are designed and built to the Saudi Building Code SBC 304, including its reinforcement detailing requirements in seismic zones, with loads taken from SBC 301. Steel complies with ASTM A615 and ready-mix concrete with ASTM C94, and compressive strength is tested on cylinder specimens to ASTM C39. The project specification sets the permitted deviation from plumb.

What moves the rate

Common pricing mistakes

A published price for its main material

The monthly Kingdom-wide average as published by the General Authority for Statistics, with its monthly series: 350 K Normal Concrete

Related calculators and terms

More items in Superstructure concrete

Price your whole bill of quantities

Upload the bill of quantities and its items are priced from published references, each with its price source.

Start nowجرّب بلا تسجيل