Chain-link fence in the bill of quantities
| Unit | lin. m |
|---|---|
| Category | Gates and metal fences |
| Division | Metal and steel works |
The item as worded in the bill
Supply and install chain-link fence 2 m high, of 3 mm galvanised wire with 50×50 mm mesh, on 60 mm diameter galvanised tube posts every 3 m set in 40×40×60 cm concrete footings, with strain posts and raking braces at corners and ends and three horizontal tension wires, including excavation, concrete and all fixing accessories.
Method of measurement
Measured by linear metre along the fence centreline at ground level between end posts, following the ground slope, with the height stated in the description. Gate openings are deducted and gates counted by number. Nothing is added for posts, braces, footings or overlaps of mesh rolls. Barbed wire arms and strands are part of the item if mentioned in the description.
What the unit rate covers
- Chain-link mesh
- Line posts, strain posts and braces
- Tension wires, stretcher bars and tie wires
- Excavation and concrete footings
- Setting out the line
- Barbed wire where given in the description
Priced separately
- Gates
- Clearing and grading the fence line
- Concrete plinth or kerb under the fence
- Screening fabric over the mesh
Specification and reference
It is governed by the project specification and the manufacturer’s data sheet for wire diameter, mesh size, zinc coating weight or plastic coating, post diameter and wall thickness, and footing size. Where the fence is covered with fabric, posts and footings are checked for wind loads under SBC 301 and for the site soil under SBC 303.
What moves the rate
- Fence height
- Wire diameter and protection: galvanised or plastic coated
- Post spacing and size
- Ground nature: sand or rock
Common pricing mistakes
- Pricing mesh and line posts only, although every corner, end and gate needs a heavier strain post with braces.
- Assuming excavation in sand while the site is rocky and needs breaking or drilling for each footing.
- Forgetting that covering the fence with screening fabric multiplies the wind load; posts and footings for bare mesh are not enough.
- Ignoring the zinc coating weight; light commercial mesh rusts quickly in coastal areas and sabkha soil.
More items in Gates and metal fences
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.
Start nowجرّب بلا تسجيل