العربية Try the demo Start now
Home › BOQ items guide › Waterproofing and thermal insulation › Joints and waterstops

Joints and waterstops in the bill of quantities

Joints divide into expansion joints, which split the building into parts that move independently; construction joints, formed where a pour stops; and control joints in floors and long walls. Expansion joints are treated with a compressible filler board, flexible sealant and metal covers in the finishes. Joints of water-retaining structures such as tanks and basements receive polyvinyl chloride waterstops embedded in the concrete, or swelling strips bonded to hardened concrete before the next pour. The type is chosen by the joint’s movement and the water pressure.

Where it sits in the bill and what comes before it on site

These items appear in the waterproofing section or with the concrete. Waterstops and filler boards are placed during formwork and before pouring, whereas sealants and joint covers are executed at the finishing stage once the concrete is dry and the joint cleaned.

Items in this category

ItemUnit
Expansion jointslin. m
Waterstops in construction jointslin. m

What is often left out when pricing it

Frequently asked questions

Is waterstop measured in construction joints that are not drawn?

Waterstops in construction joints the contractor chooses for his own convenience are not normally paid unless on the drawings or instructed by the engineer. Estimate the likely pour breaks in the walls and raft, and carry their waterstops in your rate if the bill is silent.

Why does the expansion joint rate differ from one location to another?

The treatment differs entirely: a floor joint needs a load-bearing metal cover, a wall or ceiling joint a lighter one, a roof joint a raised waterproofing detail, and a façade joint a sun-resistant sealant. Each location should have its own item; if the bill lumps them, analyse each type and take a length-weighted average.

What is the difference between an embedded waterstop and a swelling strip?

An embedded waterstop is a PVC strip fixed in the formwork, half cast into each pour, suiting construction or expansion joints by its profile. A swelling strip, bonded to hardened concrete, swells in water to seal the joint; it suits construction joints only and takes no movement. Neither is swapped without the engineer’s approval.

Related calculators and terms

Other categories in Waterproofing and thermal insulation

Price your whole bill of quantities

Upload the bill of quantities and its items are priced from published references, each with its price source.

Start nowجرّب بلا تسجيل