Water heaters in the bill of quantities
| Unit | No. |
|---|---|
| Category | Water supply network |
| Division | Plumbing and drainage |
The item as worded in the bill
Supply and install an electric storage water heater of 80 litres capacity, with a lined and insulated inner tank, thermostat and thermal cut-out; the rate includes the safety relief valve and its discharge pipe, two isolating valves, flexible connectors, hanging brackets, connection to the electrical point provided, commissioning and testing; the heater shall carry the approved energy efficiency label.
Method of measurement
Measured by number, each capacity and type separately (electric storage, instantaneous, solar, central). The count covers the complete heater with the accessories named in the description; the supply pipes reaching it are not included but measured under the pipe items. In central systems the calorifier, circulation pump and control panel are each measured under their own item, and solar collectors by number or by set as described.
What the unit rate covers
- Heater of the specified capacity and rating
- Pressure and temperature relief valve with its discharge pipe
- Isolating valves and flexible connectors
- Hanging brackets or base
- Final electrical connection and testing
Priced separately
- The electrical point with its breaker and switch
- Cold and hot supply pipes up to the heater
- Return line and its pump in central systems
Specification and reference
Installation is governed by SBC 701 and energy efficiency by SBC 601 or SBC 602 according to building type; the heater must carry the energy efficiency label issued by the Saudi Standards, Metrology and Quality Organization. A pressure and temperature relief valve discharging visibly to a safe place is required, and the electrical connection and earthing must meet SBC 401.
What moves the rate
- Capacity and heater type (storage, instantaneous, solar)
- Inner tank material, lining and warranty period
- Location: above a false ceiling or on the roof
- Energy efficiency class
Common pricing mistakes
- Pricing the heater without the relief valve and its discharge pipe to the nearest drain; both are a handover condition, not an optional extra.
- Assuming the electrical point is adequate, then finding the instantaneous heater’s rating needs a larger cable and breaker than those installed.
- Omitting the drip tray and its drain under a heater above a false ceiling, so the ceiling is damaged at the first leak.
- Not checking that the bracket and wall can carry the heater when full, particularly on hollow block.
Related calculators and terms
More items in Water supply network
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.