Tanks and pumps in the bill of quantities
Most buildings in Saudi Arabia rely on a ground tank fed from the mains or tankers, and a pump that lifts water to a roof tank or pressurises the network directly. The ground tank may be concrete within the structure, priced under concrete and waterproofing, or prefabricated in polyethylene or assembled glass-fibre panels. Pumps are either a simple float-controlled transfer pump or a booster set of two or more pumps with a pressure vessel and control panel; the system is chosen by building height and number of units.
Where it sits in the bill and what comes before it on site
Its items come after the supply network or in the mechanical equipment section. Before installation, concrete plinths and roof or pump room waterproofing must be complete, the power supply ready, and openings for bringing in the tanks secured before the building is closed.
Items in this category
| Item | Unit |
|---|---|
| Prefabricated water storage tanks | No. (or m³ of capacity for sectional tanks) |
| Water booster pumps | No. (set) |
What is often left out when pricing it
- Concrete plinths or galvanised steel frames under roof tanks, which carry the full weight of the water.
- Electrical and mechanical float valves and the control cable between the roof tank and the pump panel at ground level.
- Overflow, drain and screened vent lines, and the wash-out valve at the bottom of every tank.
- Disinfecting tanks before commissioning, and flexible connectors and vibration isolators on pump suction and discharge.
Frequently asked questions
The ground tank is concrete on the drawings; where is it priced?
A concrete tank is priced under the reinforced concrete and excavation items, plus internal waterproofing suitable for potable water, external waterproofing, the access cover and ladder. The plumbing bill keeps the inlet, suction and overflow pipework and the float valve. Check the internal lining is named in one bill; it often falls between them.
Who fixes the tank capacity and pump duty?
The designer fixes them from the number of users, daily consumption and required days of storage, and from the flow and pressure needed at the most remote fixture. The estimator does not change these values but checks that the pump offered meets the duty point in the equipment schedule, not just the nominal motor rating.
Do the pump control panel and its cables belong to electrical or plumbing works?
By custom the control panel is supplied with the pump set under the plumbing item, being part of the equipment, and the electrical contractor brings the feeder cable up to the panel. Control cables between the panel, floats and pressure sensors follow the pump item. Check the scope boundary in the specification and between subcontractors.
Related calculators and terms
Other categories in Plumbing and drainage
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.
Start nowجرّب بلا تسجيل