العربية Try the demo Start now
Home › BOQ items guide › Doors, windows and aluminium › Steel and fire-rated doors › Fire-rated door

Fire-rated door in the bill of quantities

UnitNo.
CategorySteel and fire-rated doors
DivisionDoors, windows and aluminium

The item as worded in the bill

Supply and install single-leaf steel door, fire-rated for 90 minutes, size 100×220 cm, leaf of 1.2 mm galvanised steel sheet with rock wool core, frame of 1.5 mm steel sheet grouted with mortar, with smoke seals, including hinges, self-closer, emergency push bar and test label, from a factory approved by Civil Defense.

Method of measurement

Measured by number per type according to the door schedule and the life-safety plan, the description stating the rating period, size, number of leaves and any vision panel. Each rating period is a separate type even if the size is the same. It is not measured by square metre, and the hardware set is part of the item where stated, being part of the tested assembly.

What the unit rate covers

Priced separately

Specification and reference

SBC 201 and SBC 801 set the door’s rating period according to the rating of the wall in which it sits. The door is supplied as a tested assembly bearing a label from a recognised body and installed to NFPA 80 without any site modification; approval of the factory and product by Civil Defense is required before supply.

What moves the rate

Common pricing mistakes

Related calculators and terms

More items in Steel and fire-rated doors

Price your whole bill of quantities

Upload the bill of quantities and its items are priced from published references, each with its price source.

Start nowجرّب بلا تسجيل