Steel and fire-rated doors in the bill of quantities
This category covers doors made of galvanised steel sheet with an internal core, in two kinds: fire-rated doors, tested as a complete assembly of leaf, frame and hardware and carrying a label stating the rating period, and plain steel doors for service rooms and roofs. Fire-rated doors are used at escape stairs, protected corridors, electrical rooms and shafts according to the life-safety plan, while a plain steel door is enough for pump rooms, tank rooms and stores where the wall needs no fire rating.
Where it sits in the bill and what comes before it on site
They appear in the metal doors section or with fire protection works, ordered by the door schedule. Steel frames are fixed during or right after wall construction and grouted, and leaves are installed after plastering and before final painting.
Items in this category
| Item | Unit |
|---|---|
| Fire-rated door | No. |
| Steel door for service rooms | No. (or m²) |
What is often left out when pricing it
- The fire-listed hardware set: hinges, self-closer, emergency push bar and smoke seals.
- Test certificates, the rating label and the factory’s Civil Defense approval within the supply documents.
- Grouting the steel frame with mortar, its wall anchors and sealing the gap around it.
- Fire-rated glass in vision panels, which costs far more than ordinary glass.
Frequently asked questions
Can a fire-rated door be priced as a plain steel door with an insulating core?
No. The fire rating is granted to a complete tested assembly of leaf, frame, hardware, glass and seals, bearing a label from a recognised testing body. The rate is therefore taken from a factory approved by Civil Defense; a locally made door without certification is rejected at submittal or at inspection.
Who decides the fire rating period required for each door?
It is set by the life-safety plan and the door schedule, following the rating of the wall containing the door under SBC 201 and SBC 801. The contractor prices what the schedule states; if a door on an escape stair or protected corridor has no rating, a query is raised at tender stage.
How are steel doors measured in the bill of quantities?
They are measured by number per type, the description stating size, number of leaves, sheet thickness, fire rating if any, and any vision panel or ventilation louvre. Each difference in one of these makes a separate type with its own rate; single and double doors must not be grouped under one rate.
Related calculators and terms
Other categories in Doors, windows and aluminium
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.
Start nowجرّب بلا تسجيل