Double-glazed aluminium windows in the bill of quantities
| Unit | m² (or No.) |
|---|---|
| Category | Windows |
| Division | Doors, windows and aluminium |
The item as worded in the bill
Supply and install two-sash sliding aluminium window, size 150×150 cm, of thermally broken sections with electrostatic powder coating, double glazed 6 mm + 12 mm cavity + 6 mm heat-reflective glass, including rollers, locks, weather seals, insect screen, fixing and sealant both sides, complying with energy conservation requirements.
Method of measurement
Measured by square metre on the overall frame size, width by height, as per the window schedule, or by number per type. Mullions and transoms are not deducted and nothing is added for a concealed subframe or sill. Arched windows are usually measured on the smallest enclosing rectangle. Fabrication sizes are taken on site after plastering, and glass and accessories are not measured separately.
What the unit rate covers
- Coated aluminium sections and the subframe, if any
- Double glazing of the specified make-up
- Rollers, hinges, locks and handles
- Rubber gaskets and brush seals
- Insect screen where stated
- Fixing, sealant and cleaning
Priced separately
- Marble or granite sills
- Steel grilles or external shutters
- Internal blinds and curtains
Specification and reference
SBC 601 and SBC 602 set the maximum thermal transmittance and solar heat gain coefficient for windows, SBC 201 requires safety glass in hazardous locations, and wind loads are taken from SBC 301. The project specification defines the section alloy, usually 6063, the coating thickness and the glass make-up.
What moves the rate
- Section series and presence of a thermal break
- Glass type: low-emissivity, tinted or tempered
- Opening system: sliding, hinged or fixed
- Coating type, colour and size
Common pricing mistakes
- Pricing a section without thermal break and with ordinary glass, which fails the energy conservation requirements and is rejected at material approval.
- Taking the quantity on the visible glass area while the bill measures the overall frame size, or the reverse.
- Overlooking tempered glass in windows near floor level and in bathrooms, where safety glass is required.
- Fabricating windows from drawing sizes without surveying openings after plastering, so differences appear and are fixed at the contractor’s cost.
A published price for its main material
The monthly Kingdom-wide average as published by the General Authority for Statistics, with its monthly series: Aluminum (Saudi, Arch side)
Related calculators and terms
More items in Windows
Price your whole bill of quantities
Upload the bill of quantities and its items are priced from published references, each with its price source.
Start nowجرّب بلا تسجيل